Insulation Calculator

Work out how thick your insulation should be and how many bags to buy.

Last updated 2026-11-28 · How we calculate this

Enter the Area and R-Values

Measurement system
The length of the attic floor, wall or floor. For a wall, use its length.
The width of the attic floor or floor. For a wall, use its height.
R (US)
From your local code or the Energy Star chart: R-38 to R-60 is usual for US attics. In Metric this is RSI, from 0.18 to 17.61.
R (US)
Depth of the old insulation × its R-value per inch. Leave blank if there is none.
Typical values. λ is the thermal conductivity in W/m·K printed on UK and European packs.
The area one bag or roll covers at your R-value, from the chart on the pack. Leave blank to skip the count.
%
Extra for trimming and gaps, from 0 to 100. Leave blank for none.

Insulation Needed

Enter the area and R-values to see the insulation needed.

This is a planning estimate. R-values per inch are typical figures, and every product has its own, so use the R-value, thickness and coverage printed on the pack when you have it. The calculator does not allow for joists, studs or rafters, which carry heat past the insulation, or for air leaks, which should be sealed first. Building codes, ventilation, vapor control and fire rules vary, so check them with your local building department or installer.

Quick Answer

Take the R-value you already have away from the R-value you want, then divide by the R-value per inch of the insulation you plan to use. Going from R-11 to R-49 with cellulose at R-3.5 per inch means adding R-38, which is 38 ÷ 3.5 = 10.9 inches.

How to Use This Calculator

Measure the length and width of the attic floor, wall or floor you want to insulate. Enter the R-value you are aiming for and the R-value already there, if any, then choose the kind of insulation. The calculator works out the R-value to add and how thick the new layer needs to be. If you enter the area one bag or roll covers at that R-value, from the chart on the pack, it also counts the bags or rolls to buy with a small allowance for waste. In Metric the R-values are shown as RSI and the thickness in millimeters.

  1. Enter the length and width of the area to insulate.
  2. Enter the R-value you want and the R-value already there.
  3. Choose the insulation type, and enter the coverage per bag or roll from the pack.
  4. Read the thickness to add and the bags or rolls to buy.

The Formula

Thickness = (R-value you want − R-value already there) ÷ R-value per inch; Bags or rolls = area × (1 + waste % ÷ 100) ÷ coverage per bag, rounded up

R-value measures how well a layer resists heat passing through it, and layers add up: two layers of R-19 make R-38. So the R-value to add is simply the target minus what is already there. Fibrous insulation gives roughly the same R-value for every inch of thickness, so dividing the R-value to add by the R-value per inch gives the thickness. In Metric the same sum uses RSI, the metric R-value, where R-1 in US units is 0.176 RSI. The bag count uses the coverage from the pack because each product is packed differently.

Worked Example

An attic 40 ft × 30 ft (1,200 sq ft) has R-11 and needs R-49, so R-38 has to be added. With cellulose at R-3.5 per inch that is 38 ÷ 3.5 = 10.9 in (275.8 mm). If the bag chart says one bag covers 40 sq ft at R-38, you need 1,200 × 1.05 ÷ 40 = 31.5, so 32 bags.

With fiberglass batts at R-3.1 per inch, the same R-38 needs 38 ÷ 3.1 = 12.3 in, which is why a thicker layer of batts gives the same result as a thinner layer of cellulose.

UK loft in Metric: RSI 2.0 already there and a target of RSI 6.0 means adding RSI 4.0 (R-22.7). With mineral wool rolls at λ 0.044, that is 174.8 mm, so a 200 mm roll laid across the joists does the job.

Frequently Asked Questions

What R-value do I need?

It depends on your climate and where the insulation goes. Energy Star suggests about R-30 to R-49 for an attic in the warmest US zone, rising to R-49 to R-60 in the coldest, with walls usually R-13 to R-21. In the UK the Energy Saving Trust recommends 270 mm of mineral wool in a loft. Your local building code sets the minimum.

How do I find the R-value of the insulation already there?

Measure how deep it is in a few places and multiply by its R-value per inch. Six inches of loose fiberglass at about R-2.5 per inch is roughly R-15, and old batts that have been squashed or soaked are worth less. If you are unsure what it is, treat it as a little less than it looks.

Does loose-fill insulation settle?

Yes, especially cellulose, which sinks a little over the first months. In the US the Federal Trade Commission requires loose-fill bags to give the minimum settled thickness for each R-value, so blow it to at least the starting depth on the chart. Rulers stapled to the joists make the depth easy to check.

Should I use batts or loose fill?

Batts and rolls suit open joists and studs at standard spacing with few obstructions, and they are easy to lay by hand. Loose fill flows around wires, pipes and odd gaps, which makes it good for topping up an attic that already has some insulation. It is blown in with a machine, which many stores rent out.

What is RSI, and how does it relate to a U-value?

RSI is the R-value in metric units, square meters times kelvins per watt, and R-1 in US units is about RSI 0.176. A U-value, used in UK and European rules, is the heat that passes through the whole wall or roof, so lower is better. For a whole construction, U is one divided by the total RSI of all its layers.

Why should I not squash batts to fit?

A batt reaches its R-value only at its full thickness, because the trapped air does the insulating. Pressing an R-30 batt into a space meant for R-19 loses much of the gain, and the US Department of Energy warns that compressed insulation performs worse. Choose a batt made for the depth of your joists or studs.

Sources: US Department of Energy, Energy Saver: Insulation (R-values per inch); ENERGY STAR, Recommended Home Insulation R-Values; Federal Trade Commission, R-Value Rule (16 CFR Part 460); Energy Saving Trust, Roof and loft insulation (recommended loft depth); NIST Guide to SI, Appendix B (conversion factors)