Insulation Calculator
Work out how thick your insulation should be and how many bags to buy.
Last updated 2026-11-28 · How we calculate this
Insulation Needed
Enter the area and R-values to see the insulation needed.
This is a planning estimate. R-values per inch are typical figures, and every product has its own, so use the R-value, thickness and coverage printed on the pack when you have it. The calculator does not allow for joists, studs or rafters, which carry heat past the insulation, or for air leaks, which should be sealed first. Building codes, ventilation, vapor control and fire rules vary, so check them with your local building department or installer.
Quick Answer
Take the R-value you already have away from the R-value you want, then divide by the R-value per inch of the insulation you plan to use. Going from R-11 to R-49 with cellulose at R-3.5 per inch means adding R-38, which is 38 ÷ 3.5 = 10.9 inches.
How to Use This Calculator
Measure the length and width of the attic floor, wall or floor you want to insulate. Enter the R-value you are aiming for and the R-value already there, if any, then choose the kind of insulation. The calculator works out the R-value to add and how thick the new layer needs to be. If you enter the area one bag or roll covers at that R-value, from the chart on the pack, it also counts the bags or rolls to buy with a small allowance for waste. In Metric the R-values are shown as RSI and the thickness in millimeters.
- Enter the length and width of the area to insulate.
- Enter the R-value you want and the R-value already there.
- Choose the insulation type, and enter the coverage per bag or roll from the pack.
- Read the thickness to add and the bags or rolls to buy.
The Formula
Thickness = (R-value you want − R-value already there) ÷ R-value per inch; Bags or rolls = area × (1 + waste % ÷ 100) ÷ coverage per bag, rounded up
R-value measures how well a layer resists heat passing through it, and layers add up: two layers of R-19 make R-38. So the R-value to add is simply the target minus what is already there. Fibrous insulation gives roughly the same R-value for every inch of thickness, so dividing the R-value to add by the R-value per inch gives the thickness. In Metric the same sum uses RSI, the metric R-value, where R-1 in US units is 0.176 RSI. The bag count uses the coverage from the pack because each product is packed differently.
Worked Example
An attic 40 ft × 30 ft (1,200 sq ft) has R-11 and needs R-49, so R-38 has to be added. With cellulose at R-3.5 per inch that is 38 ÷ 3.5 = 10.9 in (275.8 mm). If the bag chart says one bag covers 40 sq ft at R-38, you need 1,200 × 1.05 ÷ 40 = 31.5, so 32 bags.
With fiberglass batts at R-3.1 per inch, the same R-38 needs 38 ÷ 3.1 = 12.3 in, which is why a thicker layer of batts gives the same result as a thinner layer of cellulose.
UK loft in Metric: RSI 2.0 already there and a target of RSI 6.0 means adding RSI 4.0 (R-22.7). With mineral wool rolls at λ 0.044, that is 174.8 mm, so a 200 mm roll laid across the joists does the job.
Frequently Asked Questions
Sources: US Department of Energy, Energy Saver: Insulation (R-values per inch); ENERGY STAR, Recommended Home Insulation R-Values; Federal Trade Commission, R-Value Rule (16 CFR Part 460); Energy Saving Trust, Roof and loft insulation (recommended loft depth); NIST Guide to SI, Appendix B (conversion factors)